Multibeton Underfloor Heating Design

Multibeton carry out a full design service for underfloor heating from preliminary outline proposals through to fully detailed coil design drawings. Full consideration is given to the type of building and usage together with the various types of floor finish which can include Carpet, Vinyl, Timber, Stone, Marble etc

Underfloor heating has a very high radiant heating component and this means that comfort conditions will be achieved at a lower ambient temperature that other types of heating such as convective. As described in the CIBSE guide this lower mean radiant temperature can be used for heat loss calculations when installing Multibeton underfloor heating enabling a 10-15% reduction in energy requirements.

Since underfloor heating provides a comfortable temperature at floor level where it is most needed the building height has less effect on the design and no allowance need be made for stack effect in high buildings such as Atria. This reduces the high ceiling and roof temperatures associated with convective systems and further increases the savings in energy costs.

Physiology of Heating

The purpose of every heating system is to provide comfortable indoor conditions, whereby physiological criteria are fulfilled. For example it is accepted that to be comfortable within a given environment it is necessary for a greater degree of warmth to be provided to the lower part of the body that the upper (warm feet - cool head). It is equally important that there is a low temperature difference between the temperature of the air within the room and the surface temperature of the surrounding walls.

The requirements for comfortable room surroundings are represented in graph form by the vertical temperature profile "Ideal curve" shown in figure 1. The various profiles show the temperature layers for typical types of heating systems, from floor to ceiling. If we compare the temperature profiles of various heating systems occurring in practice, with the theoretical optimum profile No 1 then we sometimes find pronounced variations. The temperature profile for underfloor heating is the only curve which almost perfectly coincides with the ideal.

By comparison heating by radiators only causes unnecessary high temperatures at head and ceiling level, while the floor remains cold to the feet.

Expensive carpets are often used to counter the cold floor effect often experienced in many buildings whilst with underfloor heating you are free to choose from a wider selection of flooring materials.

Radiant floor heating makes it possible to achieve comfort conditions at lower air temperature than would otherwise be the case. This reduces energy consumption and provides a comfortable and healthy environment where people need it.

With today's higher standards of installation for our buildings high temperature radiators of smaller and smaller sizes can no longer provide an even distribution of heat within the space, whilst underfloor heating with low operating and surface temperatures can provide a cost effective solution with lower energy consumption for our buildings.

1. Theoretical Ideal heating curve.
2. MULTIBETON underfloor heating.
3. Heating by radiators internal walls.
4. Heating by radiators external walls.
5. Warm air heating.
6. Ceiling heating.
 